01 / Explore your circuit

CIP Simulator

Your circuit

INPUTS ↓
Actual ID
Inside diameter 1.870 in

Sanitary tubing presets use the Sani-Matic ID table. For other tubing or pipe schedules, enter a custom ID.

US gpm
060120 gpm

Direct flow entry sets the 100% pump-flow reference. Use pump speed below to vary actual flow.

100%
0% / stopped100%

100% flow reference: 50.0 US gpm

Simulation: flow scales with speed. No pump or system curve is solved.

One circular, liquid-full pipe. Constant flow; no parallel-branch distribution assumed.
Your CIP circuit / SIMULATION
Supply source
Wash tank chemical feedOff holds the stored wash solution
TIC-101 / Temperature PIDWash inlet 113.0°F
°F
Try a setpoint
Two-tank CIP skid and process loopWash solution flows from the wash tank through a supply pump, flow meter, and heater to the selected process pipe. A separate return flows through a conductivity sensor to the wash tank. Rinse and drain branches are inactive. Select a component for design context. CIP SKID / TWO-TANK RECIRCULATIONPROCESS CIRCUIT RINSE ISOLATED DRAIN / CLOSED RinseWATERTK-101 Wash solution4.00 mS/cm113.0°FSELECTED SOURCETK-102 CHEM. OFF Pump · 100%P-101 FT10150.0 gpm 0%STEAM SUPPLY0 lb/hTV-101CONDENSATEHX-101 TIC101SP 167°F113.0°FTT101 4.00 mS/cmCT102RETURN 107.6°FSUPPLY → SELECTED PIPE2.0 in tubeID 1.870 in5.84 ft/sCLICK TO EDIT ↗LINE-101
TT-101 / CIP supply113.0°F
Circuit return107.6°F
Steam flow0lb/h0 kW delivered
TV-101 / Steam valve0.0%
Wash tank temperature113.0°FHolding250 US gal mixed tank
Heat exchanger ΔT0.0°F54.0°F needed to setpoint
Steam needed at setpoint1,658 lb/h4,409 lb/h available

Recovered return warms the wash tank and reduces steam demand.

Heat off · steam valve closed.

Live temperature trend Supply · Return · Wash tank · Setpoint
● Supply● Return● Wash tank┄ Setpoint15 seconds of simulated response
212°F68°F
Wash tank · stored4.00mS/cmSelected source
CT-102 · return4.00mS/cmWash solution at return sensor
Illustrative inlet → CT delay6.0 sSelected source fills the loop
Return → wash tank · recirculating
Wash is recirculating. Injection is off; stored conductivity is retained.

Illustrative demo: 0.20 mS/cm rinse water, 4.00 mS/cm initial wash. Timing is scaled for visibility, not calculated from pipe length. Thermal demo starts the wash tank at 45°C and mixes recovered return into a fixed 250 US gal (946 L) working volume. Rinse starts at 20°C. Steam is limited to 2,000 kg/h; return is delayed and 3°C below supply. Tank levels, dilution, and equipment sizing are not solved.

Click either tank to switch supply, or the dosing pump to toggle injection.

Average pipe velocity
5.84ft/s

1.78 m/s

✓ Meets 5 ft/s reference
Flow at 5 ft/s
42.8gpm

Sani-Matic velocity reference

Flow at 7 ft/s
59.9gpm

Additional comparison target

Reference targets, not a cleaning validation. 5 ft/s is the guideline cited in the linked article; 7 ft/s is included for comparison. Confirm the installed ID and circuit requirements. Calculation basis ↗

Go deeper: circuit volume & Reynolds number Optional engineering checks using your fluid properties
ft
kg/m³
cP

Defaults approximate water at 20°C. Enter properties at your CIP temperature and concentration. Volume covers this uniform pipe only; travel time is not a cleaning contact time.

14.3US gal
17.1seconds
84,600Turbulent estimate

02 / Compare pipe sizes

The right flow for every line.

See how the same flow performs across tube sizes.
Select a row to update your circuit.

Calculated flow requirements by sanitary tube diameter
Tube outside diameterInside diameterFlow at 5 ft/sFlow at 7 ft/sVelocity at 50 gpmCompare
Flows calculated from the listed IDs; displayed values are rounded. Presets are dimensional examples, not a universal tube or pipe specification.Sani-Matic reference ↗
Calculation method & engineering assumptions
A = π × ID² / 4v = Q / AQtarget = vtarget × A

Velocity is the cross-sectional average for steady incompressible flow in one completely liquid-filled circular pipe. Calculations use actual inside diameter. US mode uses US gallons; metric mode uses litres and SI dimensions. Conversion basis: 1 US gal = 0.003785411784 m³; 1 in = 0.0254 m; 1 ft = 0.3048 m. Calculations retain full precision; displays are rounded.

Optional checks use Re = ρvD / μ and pipe volume = A × length. The flow-regime labels use approximate boundaries of Re < 2,300 (laminar), 2,300–4,000 (transitional), and > 4,000 (turbulent). These approximate regime boundaries follow Caleffi’s flow-regime explanation. A turbulent estimate is not proof of cleaning effectiveness. The main calculator evaluates one pipe segment. The independent design toolkit adds an estimated pressure duty and assigned branch-flow examples; pump capability, pressure-balanced branch distribution, spray coverage and partly filled return flow still require separate assessment.

Temperature PID & pump simulation assumptions

The temperature demo uses an exchanger energy balance with water-like density 998 kg/m³ and specific heat 4.18 kJ/(kg·K). The valve is limited to 2,000 kg/h; assumed steam latent heat is 2,100 kJ/kg with 90% delivered efficiency. The heat balance follows the approach described in Spirax Sarco’s heat-load and steam-load explanation. The illustrative PID includes flow feed-forward, derivative filtering, output limits, and conditional integration to limit windup (see MathWorks’ anti-windup explanation). These are demonstration assumptions and gains, not a steam-property calculation, pump curve, heat-exchanger rating, or field controller tune. The circuit return is a delayed supply reading minus 3°C (floor 20°C). Return flow contributes to the wash tank energy balance only while the recovery valve is open, using its additional travel time to the tank. The wash tank begins at 45°C with a fixed 250 US gal (946.35 L) working volume and a 0.15 kW/K heat-loss coefficient to 20°C ambient. Its thermal balance is Ctank dT/dt = ṁ cp(Treturn − Ttank) − UA(Ttank − Tambient), with the return term zero when diverted to drain. Rinse supply remains at 20°C. Tank levels and chemical dilution remain outside this illustrative model. Heater ΔT is the liquid supply temperature minus its inlet temperature; a warmer wash inlet reduces the rise and steam required to hold the same supply setpoint.

How to use the 5 ft/s and 7 ft/s references

Sani-Matic: CIP System Design Considerations for Cleaning Pharmaceutical Equipment (August 8, 2017) provides the tube IDs used here and a 5 ft/s pipeline velocity guideline. This tool derives flow directly from those IDs, so decimal results differ from the article’s whole-number values.

The 7 ft/s (2.1336 m/s) target is an additional comparison. The linked article does not establish it as a universal requirement. Likewise, 5 ft/s (1.524 m/s) is a cited design guideline, not a declaration of ASME-BPE, 3-A, or EHEDG compliance. Higher flow can increase pressure losses and utility demand. Select the design target for the application, soils, chemistry, temperature, equipment, and validated procedure.

The two-tank schematic is an original illustration of a common CIP arrangement, with the reference article providing design context. It is not a manufacturer drawing or equipment specification. Equipment locations, levels, and motion are illustrative. The current calculation applies to the selected pipe segment only.

Basis & transparency

References, clearly separated from assumptions.

Published engineering context for an independent MTC toolkit.

Independent engineering tool. McDonald Tech Consulting developed this toolkit. Third-party names identify technical sources only; their inclusion does not imply sponsorship, endorsement, affiliation or approval. Company names and trademarks belong to their respective owners.

Use for preliminary evaluation. Results and animations support learning and design comparisons. They do not validate cleaning, select a specific product, certify compliance or replace application-specific engineering and cleaning trials. Confirm actual dimensions, device performance data and operating conditions before use in a design.

Illustrations and examples. The schematics and animations are original simplified illustrations. Supplier photos, logos, manual figures and performance curves are not reproduced. Example ratings, removal rates, utility prices and controller settings are editable assumptions, not manufacturer recommendations or test results.

01 / PIPE VELOCITY

Sani-Matic

Tube inside diameters and the 5 ft/s guideline. Flow results are calculated here from geometry; 7 ft/s is an additional comparison, not a cited requirement.

CIP design considerations · 2017 ↗
03 / HYDRAULICS

U.S. DOE & EPA

DOE supplies fluid-flow context. EPA EPANET 2.2 Table 3.3 supplies generic fitting K examples. These are not sanitary-component ratings. The toolkit estimates a required duty; it does not solve a pump operating point or suction conditions.

EPA fitting K table ↗ · Fundamentals handbook · Volume 3 ↗
04 / HEAT & STEAM

Spirax Sarco

Energy-balance context. Steam properties, delivery efficiency and heat losses in the examples are simplified assumptions, not a selected exchanger rating.

Heat-load and steam-load relationship ↗
05 / CONTROLS

MathWorks

Background on anti-windup in PID control. The controller is an independent demonstration; no MATLAB or Simulink software is embedded.

PID anti-windup explanation ↗
06 / FLOW REGIME

Caleffi

Background on approximate Reynolds-number boundaries. A turbulent-flow result alone does not demonstrate cleaning effectiveness.

Flow-regime explanation ↗

Reference links reviewed October 8, 2026. Follow the original publisher for current product documentation.

What happens to my inputs?

Calculations run in your browser. This toolkit does not send entered design values to MTC or the referenced suppliers, and it adds no analytics trackers. Inputs and comparison baselines last only for this page session; reloading clears them. Downloaded reports contain the inputs you choose and are saved on your device. Hosting and sign-in services may process normal connection and access data under their own policies. External links open the publisher’s site; the contact link opens your email app.